Optionals
Pneumatics with micro electro valves
Pneumatics and valves with very small volumes and high speeds drive: it allows great accuracy and speed on small volume pieces under test.
Pneumatics with micro electro valves
Pneumatics and valves with very small volumes and high speeds drive: it allows great accuracy and speed on small volume pieces under test.
Staubli© fittings for the connection to the front panel of calibrated leaks Leak_ID or of third parties, by Staubli® hermetic fitting.
Staubli© fittings for the connection to the front panel of calibrated leaks Leak_ID or of third parties, by Staubli® hermetic fitting.
Application of a mechanical regulator at very high precision: it can regulate pressure test with better accuracy and stability. Recommended for low pressures.
Application of a mechanical regulator at very high precision: it can regulate pressure test with better accuracy and stability. Recommended for low pressures.
Dynamic Offset Correction
Dynamic correction of the measurement error test after test. It allows to eliminate slow drift errors due to environmental conditions or errors of the test bench.
Dynamic Offset Correction
Dynamic correction of the measurement error test after test. It allows to eliminate slow drift errors due to environmental conditions or errors of the test bench.
Bluetooth Low Energy communication interface
Bluetooth Low Energy communication interface
Secondary Output of Waste (third result)
Particularly used on foundry pieces, it allows to add to the normal Good Waste threshold also a non-recoverable waste threshold (for Foundries: threshold of maximum chemical potting).
Secondary Output of Waste (third result)
Particularly used on foundry pieces, it allows to add to the normal Good Waste threshold also a non-recoverable waste threshold (for Foundries: threshold of maximum chemical potting).
Bi-manual logic Start Input
It accepts Start cycle by two separate Start signals (instead of only one) adhering to the regulations for bi-manual command EN 574. ATTENTION: Unless different annotations contained in each instrument handbooks, this sequence means to make safer the instrument utilization for single use and it cannot in any case be intended as a safe element for other parts handling (ex: presses, control cycles, etc...) connected to them.
Bi-manual logic Start Input
It accepts Start cycle by two separate Start signals (instead of only one) adhering to the regulations for bi-manual command EN 574. ATTENTION: Unless different annotations contained in each instrument handbooks, this sequence means to make safer the instrument utilization for single use and it cannot in any case be intended as a safe element for other parts handling (ex: presses, control cycles, etc...) connected to them.
USB port of Host type for the connection of a key storage for test results and for the copy of test parameters from an instrument to another one.
USB port of Host type for the connection of a key storage for test results and for the copy of test parameters from an instrument to another one.
High resolution measure
By the application of superior components and transducers , a metrologic resolution of the measure of 1.000.000 points is guaranteed.
High resolution measure
By the application of superior components and transducers , a metrologic resolution of the measure of 1.000.000 points is guaranteed.