Optionals
Pneumatics with micro electro valves
Pneumatics and valves with very small volumes and high speeds drive: it allows great accuracy and speed on small volume pieces under test.
Pneumatics with micro electro valves
Pneumatics and valves with very small volumes and high speeds drive: it allows great accuracy and speed on small volume pieces under test.
Application of a mechanical regulator at very high precision: it can regulate pressure test with better accuracy and stability. Recommended for low pressures.
Application of a mechanical regulator at very high precision: it can regulate pressure test with better accuracy and stability. Recommended for low pressures.
Pneumatic module of remote measurements
Based on Micro Electro Valves is a Pneumatic Module external to the measure equipment and aimed to minimize parasite volumes, increasing test sensibility and speed on small sizes of volume.
Pneumatic module of remote measurements
Based on Micro Electro Valves is a Pneumatic Module external to the measure equipment and aimed to minimize parasite volumes, increasing test sensibility and speed on small sizes of volume.
Internal card to interface the instrument to a Profinet network compatible with the most common industrial PLCs.
Internal card to interface the instrument to a Profinet network compatible with the most common industrial PLCs.
Internal Ethernet card to interface the equipment to an EtherCAT fieldbus controller
Internal Ethernet card to interface the equipment to an EtherCAT fieldbus controller
Bluetooth Low Energy communication interface
Bluetooth Low Energy communication interface
Bi-manual logic Start Input
It accepts Start cycle by two separate Start signals (instead of only one) adhering to the regulations for bi-manual command EN 574. ATTENTION: Unless different annotations contained in each instrument handbooks, this sequence means to make safer the instrument utilization for single use and it cannot in any case be intended as a safe element for other parts handling (ex: presses, control cycles, etc...) connected to them.
Bi-manual logic Start Input
It accepts Start cycle by two separate Start signals (instead of only one) adhering to the regulations for bi-manual command EN 574. ATTENTION: Unless different annotations contained in each instrument handbooks, this sequence means to make safer the instrument utilization for single use and it cannot in any case be intended as a safe element for other parts handling (ex: presses, control cycles, etc...) connected to them.
USB port of Host type for the connection of a key storage for test results and for the copy of test parameters from an instrument to another one.
USB port of Host type for the connection of a key storage for test results and for the copy of test parameters from an instrument to another one.
High resolution measure
By the application of superior components and transducers , a metrologic resolution of the measure of 1.000.000 points is guaranteed.
High resolution measure
By the application of superior components and transducers , a metrologic resolution of the measure of 1.000.000 points is guaranteed.